“CROWN” made DIGITAL MILLI OHM METER is useful for accurate measurement of low resistance of copper wire conductors , cables, coil , heater element , contact resistance of switch relays etc. Four terminal measurement system ensures error free reading without effect of test lead resistance.

SPECIFICATION :

RANGE                                      :        0.1 mill Ohm to 199.9K Ohm in 7 Range

            RANGE                                              TEST CURRENT

            0 - 199.9 m Ohm                                           1A
            0 - 1.999     Ohm                                           100 mA
            0 - 19.99     Ohm                                           10 mA
            0 - 199.9     Ohm                                           1 mA
            0 - 1.999 K Ohm                                            100 mA
            0 - 19.99 K Ohm                                            10 mA
            0 - 199.9 K Ohm                                            1 mA


ACCURACY                                      :           ± 0.2% ± 2 Digit

RESOLUTION                                   :           1 In 1999 Count

DISPLAY                                            :           3 ½ Digit 12.5 mm Height LED

POWER                                             :           230V AC ± 10%

Connect to us on  

Digital Micro Ohm Meter

/ /




For further details or requirements, Email us or send Enquiry


“CROWN” made DIGITAL MICRO OHM METER is a compact high reliability 3 ½ digit instrument suitable for measurement of resistivity of copper wires from 70 SWG to 50 SWG resistance of cables , windings , coils , heater elements & contact resistance of switches , relays etc. Emphasis in the design of this instrument has been to provide quick , stable & repeatable readings of resistance . The instrument uses 4 terminal measurement so that resistance of test leads & contacts in eliminated from test results . Actual value of resistor is directly displayed on seven segment 12.5mm display.

 SPECIFICATION :-

RANGE OF MEASUREMENT       :           1 micro ohm to 19.99 K Ohm in eight ranges

     RANGE                                  NOMINAL TEST CURRENT                         ACCURACY

0 - 1999 µ Ohm                                    1.50A                                                   ± 0.3% + 2 Digits
0 - 19.99 m Ohm                                  0.75A                                                   ± 0.2% + 2 Digits
0 - 199.9 m Ohm                                  0.75A                                                   ± 0.2% + 2 Digits
0 - 1.999 Ohm                                      75mA                                                   ± 0.2% + 2 Digits
0 - 19.99 Ohm                                      7.5mA                                                  ± 0.2% + 2 Digits
0 - 199.9 Ohm                                      0.75mA                                                ± 0.2% + 2 Digits
0 - 1999 Ohm                                       0.07mA                                                ± 0.2% + 2 Digits
0 - 19.99 K Ohm                                  0.075mA                                              ± 0.2% + 2 Digits

WARM UP Time for rated accuracy = 3 min.

INPUT VOLTAGE                            :           230V AC  ± 10% 10W Approx.

OVER RANGE                                 :           Three most significant digit blank & ‘1’ appears

Connect to us on  

High Voltage Breakdown Tester

/ /




For further details or requirements, Email us or send Enquiry

SPECIFICATION :

OUTPUT VOLTAGE (AC)                         TEST CURRENT

                                    0 - 5KV                                                           30 mA
                                    0 - 5KV                                                           100 mA
                                    0 - 10KV                                                         30 mA
                                    0 - 20KV                                                         30 mA

METER                                       :         Two Digital meters to monitor voltage & Leakage Current

ACCURACY                              :           ± 1% of Reading

POWER REQUIREMENT      :           230V  AC

OPTIONAL :

TIMER                                     :           3 Digit , setable from 0 - 999 sec.

Connect to us on  

Multi Output DC Regulated Power Supply

/ /




For further details or requirements, Email us or send Enquiry

                  
SPECIFICATION :

INPUT VOLTAGE             :    230V + 10% AC 50Hz

OUTPUT VOLTAGE /       :    (A) 0-30V DC  / 2A
CURRENT                                (B) 0- +15V DC / 1A
                                                    (C) 0-5V DC /5A

LOAD REGULATION      :    + 0.05% From on load to full load

LINE REGULATION            + 0.01% for + 10% variation input voltage

OPERATING MODE        :     Independent & Tracking mode


RIPPLE                               :     Less than 1mV


METER                                   (1) Two Digital meters to monitor the output voltage & current 
                                                    output A
                                                   (2) One Digital meter to monitor the output voltage of output B, 
                                                    selectable by switch 
                                                   (3) One digital meter to monitor the voltage of output C


PROTECTION                :       Against short circuit & overload


Connect to us on  

High Voltage DC Regulated Power Supply

/ /




For further details or requirements, Email us or send Enquiry



SPECIFICATION:

                        OUTPUT VOLTAGE                     CURRENT (MAX)
                                  0 - 300V                                        5A
                                  0 - 300V                                        2A
                                  0 - 300V                                        1A
                                 
                                                             
INPUT VOLTAGE                   :      230V ± 10% AC 50Hz

OUTPUT VOLTAGE               :      Continuously Variable with Coarse & Fine Control

LOAD REGULATION (CV)   :       ± 0.05 % ± 3mV From no load to full load
LOAD REGULATION (CC)   :       + 0.05% + 1mA From no load to full load

LINE REGULATION (CV)     :       ± 0.01 % ± 3mV for +10% variation input voltage
LINE REGULATION (CC)     :       + 0.01%  + 1mA for +10% variation input voltage

RIPPLE                                    :        3mV
 
METER                                  :       Two Digital meters to monitor the output voltage & current

PROTECTION                        :        Against short circuit & over load

Connect to us on